Single-Channel Passive DC Signal Isolator
Ziegler TI-816(without power supply)
The Signal Isolator, Isolating amplifier series
Single-Channel Passive DC Signal Isolator
Ziegler TI-816(without power supply)
Signal isolator to electrically insulate an analog DC signal in the range 0(4)---20mA which depending on version is then converted to a current or voltage signal (0(4)---20 mA or 0(2)-10 V). It operates passively and does not require a separate power supply, but derives the little power energy it needs from the DC signal.
Electrical insulation of analog DC signal 0(4)---20mA- Prevents the transfer of interference voltages and currents. Solves grounding problem in meshed signal networks.
Highly accurate-performs its isolating function with negligible transmission error.
No power supply needed-saves wiring costs and is easy to install.
Small and compact-Makes best use of the available space.
Two Channel,Single/Two-pole Isolation Amplifier
Ziegler TV-808
Isolating amplifer for electrical insulation of DC signals. Processes single and two-pole and live zero signals. Provision for raising the burden and signal conversion . A version with one input and two outputs is available that enables two electrically insulated outputs to be obtained from a single input signal.
Electrical insulation between input, output and power supply, prevents falsified
Flexibility provided by more than 250 different input and output combinations selected by simply positioning soldered jumpers – Reduced stocking
Green LED signals-a power supply failure
Inputs 0---0.1 too –40mA DC & DC Voltage 0---0.06 to 0---40V also line zero & bipolar asymmetric.
Two or Three Channel passive DC signal Isolator
Ziegler TI-807
Signal isolator to electrically insulate the analog DC signal in the range 0(4)-20 mA which depending on version is then converted to a current or voltage signal (0(4)---20 mA or 0(2)-10 V. It operates passively and does not require a separate power supply, but derives the little auxiliary energy it needs from the DC signal.
Electrical insulation of analog DC signals 0(4)---20 mA. Prevents the transfer of interference voltages and currents. Solves grounding problems in meshed signal networks.
Highly accurate-performs its isolating function with negligible transmission error.
No power needed-saves wiring costs and is easy to install in existing plants.
Single or Two-Channel Configurable Transmitter
Ziegler V604
Programmable universal transmitter which converts the input variable- a DC current or voltage, or a signal from a thermocouple, resistance thermometer, remote sensor or potentiometer-to a proportional analog output signal .
Input variable (temperature, variations of resistance, DC signals) and all measuring ranges programmed using PC
Output signal range programmed using PC and the type of output signal (current or voltage) on a DLP switch
Electrical insulation between measured variable, analog output signal and power supply – Fulfils EN61010
Digital measured variable data available at the programming interface-simplifies commissioning, measured variable and signals can be viewed on site using a PC.
Single or Two-Channel Configurable Transmitter
Ziegler PT-602
Transmitter for converting the resistance of Pt 100 temperature feeler into a linear proportional output signal. Depending on the version, the Pt 100 feeler can have a two, three or four-wire connection.
Electrical insulation between measuring input, measuring output and power supply-Fulfils EN61010
Any measuring range can be set on a DIP switch and potentiometer
Signaling of open-circuit or short-circuit be Red LED